![]() If the gas line has air in it, it needs to be purged. Hire a professional to bleed all the air from the gas pipes. #Rinnai energysaver 1004f blinking red light professional# Disconnected or broken flame rodĬheck the status of the flame rod and that it is properly connected. If the ceramic sleeve has cracks or is damaged, replace it. The flame rod and the spark electrode (igniter) are firmly attached to the mounting bracket and should not be loose or misplaced. Some Rinnai water heaters have two and some, one flame rod. Wires should be without any visible signs of damages or breakage and firmly attached to the rod and electronic board. The flame rod must be in contact with the flame to function correctly. If the water heater is working properly, the flame should have a clear, blue color with a stable pattern. If the flame rod or spark electrode has deposits (carbon buildup), use the fine grit paper and cloth to clean or Scotch Brite pad. Venting, together with the unit installation, should be done by a qualified technician or a plumber and must follow the manufacturer’s specs, instructions, and code.Īn error code 12 might appear if the venting system has components not approved by the manufacturer, loose connections, or does not meet recommendations for the venting size, material, and clearances. #Rinnai energysaver 1004f blinking red light code# If, for any reason, exhaust gases start coming back instead of going out, this can lead to improper gas combustion (yellow and red-ish burner flame, followed by the unstable pattern).